Product Features
- Online installation outside the pipe, no need to stop water supply;
- Remote transmission of measurement information through 4-20mA or relay status;
- The sensor is clamped outside the tube, and there is no need to interrupt the production process during installation and disassembly, without stopping the flow or cutting off the tube. It is easy to install and maintain;
- The sensor is not in contact with the fluid, therefore it has the characteristics of being unaffected by pipeline dirt and blockage, and easy to install and maintain;
Technical Parameter
Transmitter | Type of transmitter | Standard type, explosion-proof type |
measuring range | 0~ 12m/s | |
输出 | 4-20mA output, pulse output (instantaneous flow), relay output (cumulative flow), optional Hart protocol, standard RS485 (ModBus RTU protocol, interface and protocol declared by user when ordering), data storage, GPRS multiple output options | |
accuracy | ±0.5%~±2.0%F.S | |
sensitivity | 0.0003m/s | |
repeatability | 0.1% | |
Explosion proof sign | ATEX authentication:Ⅱ2G,ExdⅡBT6,Certificate number:LCIE 09 ATEX 3088 | |
power supply | Standard type:100~240VAC,50/60 Hz ±5%,5VA Max、12~28VDC,2.5VA Max Explosion proof type:24VDC ±5%,2.5VA Max | |
work environment |
-40℃~ +75℃, humidity≤100%(RH),No condensation | |
protection grade | IP65 | |
Size and weight | Standard type:261×193×80 (mm) Explosion proof type:310×226×127(mm) | |
sensor | Sensor Type | Standard outer clamping type, high temperature outer clamping type |
Sensor temperature | standard -40℃~+121℃;high temperature -40℃~+280℃ | |
Signal cable | (standard)6m,Select the longest300m | |
Types of media | Reflector (particles or bubbles) with a content exceeding 100 ppm, and the particles are larger than 100 micrometers | |
Protection level | IP67,OptionalIP68 |