Transmitter
|
power supply
|
24VDC
|
The flow rate range can be expanded
|
0.003-12m/s, bidirectional (with metrological certification ranging from 0.3 to 5m/s)
|
output
|
4-20mA output, pulse output (instantaneous flow), relay output (cumulative flow), data storage, standard RS232 or RS485, optional Hart protocol, ModBus protocol (interface and protocol declared by user when ordering)
|
error
|
±0.5% R & nbsp; (Flow velocity>0.5 m/s)
|
±0.005 m/s (Flow velocity<0.5 m/s)
|
sensitivity
|
Flow rate: 0.0003m/s
|
repeatability
|
0.1%R
|
Explosion proof sign
|
Domestic explosion-proof certification: Exd II BT6, Certificate number: GYB081506ATEX Certification: IIG,Exd II BT6, Certificate number: LCIE 09 ATEX 3088
|
Type of transmitter
|
Explosion proof type, can be installed as a whole on the pipeline (declared at the time of ordering)
|
Size and weight
|
Size (mm): 358 × 250 × 150 Weight (kg): six
|
sensor
|
Media type
|
Actually, almost all relatively pure liquids
|
sensor temperature
|
Standard -40 ℃~121 ℃ High temperature -40 ℃~250 ℃ (external clamp type) -40 ℃~160 ℃ (plug-in type)
|
signal cable
|
(Standard) 6m, optional up to 300m in length
|
Pipe diameter specification
|
(Standard external clip) DN40~DN1000 (large diameter outer clamp) DN1000~DN4500 (insert type)& nbsp; DN65~DN4500
|
Size and weight
|
Standard size (mm): 60 × 43 × 43; Weight (Kg/pair):<0.5 Large size (mm): 80 × 53 × 53; Weight (Kg/pair):< one
|
Accessories and Optional Parts
|
Couplant
|
1 unit
|
Stainless steel straps
|
Depending on the specific pipe diameter
|